Page 10 - 2017-2018 ХИЧЭЭЛИЙН ЖИЛД ХАМГААЛСАН ОУСИС-ИЙН МАГИСТРАНТУУДЫН СУДАЛГААНЫ ТӨСЛИЙН ХУРААНГУЙ 2-Р БОТЬ
P. 10
We aim to study the biosafety of NCZD and CZD’s laboratory, staff biosafety training and
knowledge, administration of document, running out the autoclave’s steam, which is using for
sterilization and disinfection, pressure, capacity of keeping the temperature. It should be confirmed
and checked with chemical, biological indicator whether it has completely disposed waste and
pathogens, that develops an infection.
Material and methods
We plan to investigate cross-sectional study and gathered data about staff information, work duty
factors with questionnaire. The biosafety should be assessed by controlling list of the No.161
Statement for “Safety and biosafety working guidance during zoonotic infectious disease” in 2017
by Ministry of Health. The sterilization parameter should be tried with autoclaves’ manufacturer
and adjustment of setting and indicator.
Expected results
To measure the biosafety of the staff, to involve in necessary rehabilitation training, to measure
observance of document standard, hygiene habit, first aid during accident.
The appropriate workflow laboratory management, chemical substances, the state of fire and
electricity safety of staff during accident. To assess the management of protecting against
occasionally breaking out infectious pathogens from laboratory to surrounding environment and
people, the responsibility of disposal contaminated waste.
By revising the quality of the autoclave procedure, microorganisms and disposal waste with
chemical, biological indicator, it can verify the appropriate device activity, which includes
sterilization, disinfection and disposal procedures.
Key words: Laboratory biosafety, Autoclave, bio indicator, Geobacillus Steromaphilus,
ГЭНЭТИЙН НАС БАРАЛТЫН ТОХИОЛДОЛД АНАФИЛАКСИЙН УРВАЛЫН
ӨӨРЧЛӨЛТИЙГ ЭД СУДЛАЛЫН ШИНЖИЛГЭЭГЭЭР ИЛРҮҮЛЭХ НЬ
БАТБОЛД НАРАНБЯМБА
ҮНДЭСЛЭЛ
Анафилаксийн урвал нь яаралтай тусламж шаарддаг хэт мэдрэгшлийн I хэлбэрийн
1,2
урвалаар өрнөдөг амь насанд аюултай түргэн явцтай дархлааны урвал. Сүүлийн
жилүүдэд анафилаксийн тохиолдол Европд жилд 100000 хүн амд 1,5-7,9 тохиолдол, АНУ-д
3000 хүн амд тутамд 1 анафилаксийн урвал илэрч эмнэлгийн тусламж авдаг ба үүнээс 500-
1000 нас баралт бүртгэгджээ. 4-5 Гэнэт нас барсан тохиолдолд үхлийн шалтгааныг
тодорхойлох, үүнтэй холбоотой маргааныг шийдэх асуудал шүүх эмнэлгийн практикт
тохиолддог. Анафилаксийг илрүүлэх олон судалгаа шигүү мөхлөгт эс (ШМЭ)-ийг илрүүлэхэд
10